Sunny Tripower
Dispositivos Suportados
| Device Type | Variants | Modbus TCP (Ethernet) | Curtailment | Minimum device firmware version |
|---|---|---|---|---|
| Sunny Tripower | STP 3.0 | ✅ | ✅ | 4.03.07.R |
| STP 4.0 | ||||
| STP 5.0 | ||||
| STP 6.0 | ||||
| STP 8.0 | ||||
| STP 10.0 | ||||
| Sunny Tripower X | STP X12 | 03.12.15.R | ||
| STP X15 | ||||
| STP X20 | ||||
| STP X25 | ||||
| Sunny Tripower TL | STP 8000TL-10 | 02.65.02.R | ||
| STP 10000TL-10 | ||||
| STP 12000TL-10 | ||||
| STP 15000TL-10 | ||||
| STP 17000TL-10 | ||||
| STP 5000TL-20 | ||||
| STP 6000TL-20 | ||||
| STP 7000TL-20 | ||||
| STP 8000TL-20 | ||||
| STP 9000TL-20 | ||||
| STP 15000TL-30 | ||||
| STP 17000TL-30 | ||||
| STP 20000TL-30 | ||||
| STP 25000TL-30 | ||||
| Sunny Tripower TLEE | STP 10000TLEE-10 | 02.50.87.R | ||
| STP 15000TLEE-10 | ||||
| STP 20000TLEE-10 | ||||
| Sunny Tripower Core 1 | STP 50-40 | 4.01.05.R | ||
| STP 50-41 | ||||
| Sunny Tripower Core 2 | STP 110-60 | 1.01.04.R |
Cabeamento
Para cabeamento ethernet correto: Siga as diretrizes para cabeamento ethernet.
Configuração
- Conecte-se ao seu computador na mesma rede LAN que o SMA Sunny Tripower.
- No seu navegador da web, acesse o endereço IP do dispositivo.
- Faça login como "Instalador."

- Vá para a aba de parâmetros do dispositivo.

- Clique em "Editar parâmetros."
- Abra o menu suspenso "Comunicação Externa" → "Modbus" → "Serviço TCP."
- Defina "Ativado" como "Sim" e "Porta" como "502".